Sensedge Go for Outdoors Technical Specifications

(EK-300A & EK-300W)

Particulate Matter Sensor

Sensor technology

Laser particle sensor (Light scattering)

Mass concentration accuracy for PM2.5 1

0 to 30 μg/m³:            ±3 μg/m³

30 to 1000 μg/m³:    ±10 % m.v.

Mass concentration accuracy for PM10

0 to 30 μg/m³:            ±3 μg/m³

30 to 1000 μg/m³:    ±15 % m.v.

Mass concentration range

0 to 1,000 μg/m³

Mass concentration size range

PM2.5 0.3 to 2.5 μm

PM10 0.3 to 10.0 μm

Sensor output resolution

1 μg/m³

Calibration

Calibrated against standardized aerosol mix

WELL specification requirements

Adjustable particle density (K-factor) to accommodate project/region specific particulate profile.

Complies with WELL Performance Verification Guidebook to be used in WELL certification.

CO2 Sensor

Sensor technology

Non-dispersive infrared (NDIR)

Accuracy4

± 40 ppm ± 3%

Comply with ANSI/ASHRAE Standard 62.1-2022

Measurement range

400 to 5,000 ppm2

Up to 10,000 ppm extended range3

Sensor output resolution

1 ppm

CO Sensor*

Sensor technology

Electrochemical

Accuracy

0 to 20 ppm: ±1 ppm
>20 ppm: ±5%

Measurement range

0 to 100 ppm

Sensor output resolution

0.1 ppm

Target gas

CO

*Available in EK-300W
O3 Sensor*

Sensor technology

Electrochemical

Accuracy

0 to 100 ppb: ±10 ppb
>100 ppb: ±10 %

Measurement range

0 to 2,000 ppb

Sensor output resolution

1 ppb

Target gas

O3

*Available in EK-300W
NO2 Sensor*

Sensor technology

Electrochemical

Accuracy

0 to 100 ppb: ±10 ppb
>100 ppb: ±10 %

Measurement range

0 - 2,000 ppb

Sensor output resolution

1 ppb

Target gas

NO2

*Available in EK-300W
Temperature Sensor

Sensor technology

Digital sensor

Accuracy

±0.2 °C
Certified by WELL5

Measurement range

-20 - 100 °C

Sensor output resolution

0.1 °C

Relative Humidity Sensor

Sensor technology

Digital sensor

Accuracy

±2 % RH

Measurement range

0 - 100 % RH

Sensor output resolution

0.1 % RH

Atmospheric Pressure Sensor

Sensor technology

Microelectromechanical systems (MEMS) sensor

Accuracy

±0.3 hPa

Range

300 - 1100 hPa

Power

Battery

6 x Li/SOCl2 AA size

Battery Life

Up to 8 years of battery life6 using Adaptive Sampling™

3.5 years using a high frequency fixed sampling rate6, 7

USB-C

5V 0.5 A
(Cable not included)

PoE

Via PoE to USB-C converter 
(Cable not included)
Connectivity & Integration

Frequency range (MHz)

Sub-Ghz wireless communication

IN865/EU868/US915/AU915/KR920/AS923

These frequency bands cover over 200 countries, contact Kaiterra for details on compliance in your location.

Gateway

Gateway supports cellular9 and ethernet

Integration

BACnet/IP via Gateway (Coming soon)

API

 

Data Storage 
& Logging

Data Storage

Cloud storage
Local data storage: 0.5 days

Data Sampling

Adaptive Sampling™ to automatically adjust sampling frequency to maximize battery life.

Selected sensors support a configurable sampling rate from 1 minute to 24 hours.

Modules & Calibration

Compatible Modules

KM-300: Particulate Matter sensor module

KM-308: CO, NO2 & O3 sensor module

Calibration

Calibration via replaceable sensor modules

Security

Kaiterra’s platform architecture meets the most stringent security standards and is regularly subjected to 3rd party penetration tests. Read more about our security here.

Certifications

Quality

RESET Grade B

Healthy Building

Works with WELL

Environmental

ROHS

WEEE

Safety

FCC (US)

CE (Europe)

BIS (India)

TDRA (UAE)

RCM (Australia)

Size & Weight

Length

155 mm (6.1 in)

Height

35 mm (1.4 in)

Width

126 mm (5.0 in)

Weight

Sensedge Go: 388 g (0.86 lbs)
Outdoor housing: 426 g (0.94lbs)

Installation

Surface mount

Post mount

Operating Conditions

Operational temperature: -20 - 50 °C

Operational humidity: 5 to 95 %RH, non-condensing

  1. Operates with high accuracy and reliability down to temperatures of -20°C. Performance may degrade below -20°C
  2. Extended exposure to concentrations below 400 ppm may result in incorrect operation of ABC algorithm and should be avoided.
  3. Sensor provides readings in the extended range but the accuracy may be lower than that specified in the table.
  4. The accuracy specification covers environments ranging from 0-50°C and 0-80% RH, and complies with indoor air quality standards ANSI/ASHRAE Standard 62.1-2022 at 25°C.
  5. As a RESET Certified Grade B air quality monitor, this device automatically meets technical requirements for this parameter.
  6. During operating hours (9-5, Mon-Fri): one sample per minute for all sensors except particulate matter, and one sample every 10 minutes for particulate matter. Outside of operating hours: one sample every five minutes for all sensors except particulate matter sensor, and one sample every 60 minutes for particulate matter.
  7. Actual battery life may vary based on usage, environmental conditions, and other factors. Model SE-300W has a battery life expectancy of 3.5 years. Model SE-300L has a battery life expectancy of 8.5 years.